SLV-E160EE, SLV-E290EE, SLV-E290EG, SLV-E410AP, SLV-E410CP, SLV-E410EE, SLV-E410EX, SLV-E410IT, SLV-E410UX, SLV-E410VP - Sony VCR Service Manual (repair manual). Page 52

Read Sony SLV-E160EE / SLV-E290EE / SLV-E290EG / SLV-E410AP / SLV-E410CP / SLV-E410EE / SLV-E410EX / SLV-E410IT / SLV-E410UX / SLV-E410VP Service Manual online

2-4-2.
SYNC AGC Check (MA-249 Board)
Mode E-E
Signal Color 
bar
Measurement point 
Video LINE OUT terminal
Measuring instrument 
Oscilloscope
Specified value 
A=1.00 ± 0.05Vp-p
[Check Method]
1) Check that the SYNC AGC level (A) satisfies the specified
value.
Fig. 7-2-5.
2-4-3.
White Clip/Dark Clip Check (MA-249 Board)
Mode E-E
Signal Color 
bar
Measurement point 
IC201 pin #2
Measuring instrument 
Oscilloscope
Specified value 
White clip:  190 ± 15%
Dark clip:  52 ± 10%
[Check Method]
1) Check that the white clip level is 190 ± 15% to the white
(100%) level.
2) Check that the dark chip level is 52 ± 10% to the white (100%)
level.
Fig. 7-2-6.
2-4-4.
Recording Y Level Check (MA-249 Board)
Mode E-E
Signal No-signal
Measurement point 
Q214 Emitter
Measuring instrument 
Oscilloscope
Specified value 
A=550 ± 150mVp-p
[Check Method]
1) Check that the recording RF signal satisfies the specified
value.
Fig. 7-2-7.
2-4-5.
Recording Chroma Level Check 
(MA-249 Board)
Mode Recording
Signal Color 
bar
Measurement point 
IC201 pin #0
Measuring instrument 
Oscilloscope
Specified value 
A=160±28mV
[Check Method]
1) Confirm the amplitude of recording chroma level becomes the
specified value.
Fig. 7-2-8.