DCR-DVD100, DCR-DVD100E (serv.man4) - Sony Movie Service Manual (repair manual). Page 10

Read Sony DCR-DVD100 / DCR-DVD100E (serv.man4) Service Manual online

6-8
DCR-DVD100/DVD100E
COVER
COVER
1-2.
INITIALIZATION OF A, B, C, D, E, F, 1F
PAGE DATA
Note:
When reading or writing the 1F page data, select page: 0, address:
10, and set data: 01, then select F page. The 1F page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1.
INITIALIZATION OF A, B, C, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, B, C, D Page Data
Note1:
Reading/writing the C page data by using the 
 is
impossible.
Note2:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Viewfinder system adjustments
2) LCD system adjustments
3) Video system adjustments
Note3:
NTSC model: DCR-DVD100
PAL model: DCR-DVD100E
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
30 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to 75
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
00(NTSC), 80(PAL)
4
7
00
XX
Set the data. (Note4)
5
7
01
XX
Set the data, and press PAUSE
button. (Note4)
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, B,
C, D Page Data”.
Note4:
XX=20 : Initializing A page
XX=21 : Initializing B page
XX=23 : Initializing D page
XX=24 : Initializing C page
XX=28 : Initializing A, B, C and D page
2. Modification of A, B, C, D Page Data
If the A, B, C or D page data has been initialized, change the data of
the  “Fixed data-2” address of the initialized page shown in the
following tables by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, C, D Page data
Order Page Address Data
Procedure
1
0
01
00
Set the data.
2
Turn off the power and turn on
again
Note:
If the following symptoms occur after completing of the
“Modification of A, B, C, D page data”, check that the data of the
“Fixed data-2” addresses of A and D page are same as those of the
same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
Page of 52