6-7
DSC-M2_ADJ
Fig. 6-1-4
6-1. CAMERA SECTION ADJUSTMENTS
1-1.
PREPARATIONS BEFORE ADJUSTMENTS
1-1-1.
Preparations
1) Connect the equipment for adjustments according to Fig. 6-1-4.
2) Start up the application for adjustment (SEUS).
2) Start up the application for adjustment (SEUS).
Note: Be sure to set the language to “English” on the Setup screen
before performing the adjustment. (Except Japanese mod-
els)
els)
Fig. 6-1-3
Pattern box
Front of the lens
L = About 11 cm
L
Camera
PHO
TO
MO
VIE
MOD
E
Audio R (red)
Video (yellow)
Audio L (white)
Video (yellow)
Color monitor
AC IN
AC power adaptor
USB cable
(1-829-579-31)
(1-829-579-31)
Syber-shot station
UC-MB (Note)
(1-819-580-11)
UC-MB (Note)
(1-819-580-11)
HASP Key
To A/V OUT
jack
jack
To DC IN
jack
jack
DC IN jack
A/V OUT jack
USB connector
To USB
connector
connector
To USB
connector
connector
Video system Adjustment
Osilloscope
Terminated
75
Ω
PC
(The SEUS must be installed in the PC.)
OS: Windows 98/98SE/Me/2000/XP
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
RAM: 256MB or more recommended
USB: 2.0 recommended (also compatible with 1.1)
Two connectors are required.
Note: When executing “CAMERA Adjustment 1”, disassemble the Cyber-shot Station UC-MB, and make a setting by using the
Tripod adapter (J-6082-577-A) and Camera table (J-6082-384-A).