ICF-M760L - Sony Audio Service Manual (repair manual). Page 7

Read Sony ICF-M760L Service Manual online

– 7 –
SECTION  3
ELECTRICAL  ADJUSTMENTS
FM  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a reading on digital voltmeter.
L104
87.5 MHz
2.7 ± 0.1 V
Confirm
108 MHz
10.2 ± 1 V
Note
:
 Not use the FM RF signal generator in this adjustment.
FM  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L103
87.5 MHz
CT101
108 MHz
MW  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a reading on digital voltmeter.
L2
531 kHz
2.8 ± 0.1 V
Confirm
1602 kHz
8.8 ± 1 V
Note
:
 Not use the AM RF signal generator in this adjustment.
MW  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1–1
603 kHz
CT1
1404 kHz
LW  FREQUENCY  COVERAGE  ADJUSTMENT
Adjust for a reading on digital voltmeter.
CT2
153 kHz
2.3 ± 0.1 V
Confirm
279 kHz
8.1 ± 1 V
Note
:
 Not use the AM RF signal generator in this adjustment.
LW  TRACKING  ADJUSTMENT
Adjust for a maximum reading on level meter.
L1–2
162 kHz
CT3
243 kHz
AM  IF  ADJUSTMENT
Adjust for a maximum reading on level meter.
T101
450 kHz
+
level meter
set
EARPHONE jack
32 
JW104
+
digital voltmeter
• Repeat the procedures in each adjustment several times, and the
frequency coverage and tracking adjustments should be finally
done by the trimmer capacitors.
FM  SECTION
Setting:
BAND switch: FM
FM RF signal
generator
400 Hz, 30% FM modulation
frequency deviation ± 22.5 kHz
Output level: as low as possible
telescopic antenna
input
AM  SECTION
Setting:
BAND switch: MW/LW
AM RF signal
generator
400 Hz, 30%
AM modulation
Output level: as low as possible
Put the lead-wire
antenna close to
the set.
Page of 16
Display