4
5 Remaining battery/Charging 
indicator
When dry batteries are used, the 
indicator shows the remaining 
battery power.
While charging the rechargeable 
batteries an animation appears.
6 Selected message number/Total 
number of messages in the folder
7 Priority marks
Appear(s) when a message is set with 
priority mark(s).
8 Bookmark indicator
Appears when a bookmark is set for 
a message.
9 Alarm indicator
Appears when the alarm is set for a 
message.
J
Displays the EFFECT setting in the 
menu.
BA1 :  The bass sound is reinforced.
BA2 :  The bass sound is further 
reinforced.
Display window
Display during playback and stop
1Operation mode indicator
Displays the following, depending on 
the current operation mode
 : playback
 : stop
 : review/fast backward, 
cue/fast forward
 : going backward/forward 
continuously
2 Folder indicator
3 Elasped time/Remaining time 
indication/Recording date and time 
indication
4 Folder name/Message name/Artist 
name indication
K Recording mode indicator
Displays the recording mode set 
using the menu when the IC recorder 
is in the stop mode, and displays the 
current recording mode when the IC 
recorder is in the playback mode.
STHQ : Standard play stereo 
recording mode with high quality 
sound
ST : Standard play stereo recording 
mode
STLP : Long play stereo recording 
mode
SP : Standard play monaural 
recording mode
LP : Long play monaural recording 
mode
MP3 : MP3 mode (during playback 
only)
L Microphone sensitivity indicator
Displays the current microphone 
sensitivity.
 (high) : To record at a meeting or 
in a quiet/spacious place.
 (low) : To record for dictation or in 
a noisy place.
MAN (manual) : To record with 
microphone sensitivity set manually.
M Remaining recording time indication
Display during recording
N Operation mode indicator
Displays the following, depending 
on the current operation of the IC 
recorder.
 : recording
 : recording standby/recording 
pause
 : recording with the VOR 
function
 : recording pause with the 
VOR function
O Recording level meter
P Microphone sensitivity indicator
Displays the current microphone 
sensitivity when recording with AGC 
(Automatic Gain Control).
 (high) :  To record at a meeting or 
in a quiet/spacious place.
 (low) :  To record for dictation or in 
a noisy place.
Displays the recording level during 
manual recording.
Q Elapsed recording time indication
R Alarm indicator
S Recording mode indicator
Displays the recording mode (STHQ, 
ST, STLP, SP, and LP) set in the menu.
T LIM (limiter) indicator
Displays the LIMITER setting in the 
menu.
When “REC LEVEL” is set to “AUTO-
AGC,” “---” is displayed.
U Remaining recording time indication
V Remaining battery/Charging 
indicator
W LCF (Low Cut Filter) indicator
Displays the LCF setting in the menu.
1
Select “DATE & TIME” in the menu.
1
Press and hold 
/MENU.
The menu mode will be displayed in 
the display window.
2
Press 
.
 or 
>
 to select “DETAIL 
MENU” and press 
Nx
.
3
Press 
.
 or 
>
 to select “DATE & 
TIME” and press 
Nx
.
2
Press 
.
 or 
>
 to select “AUTO” 
or “MANUAL” and press 
Nx
.
When you selected “AUTO,”  the clock is 
automatically adjusted using the clock 
in the computer connected to the IC 
recorder and on which the supplied 
Digital Voice Editor software is started.
When you select “MANUAL,” proceed 
to the next steps.
Step 2: Setting the 
Clock
x
.
/
>
Nx
/MENU
You need to set the clock to use the 
alarm function or record the date and 
time.
Clock setting display appears when you 
you insert batteries after the IC recorder 
has been without batteries for a certain 
period of time. In this case, proceed from 
step 4.
3
Press 
.
 or 
>
 to select 
“08y1m1d” and press 
Nx
.
4
Press 
.
 or 
>
to set the year, 
month, day, hour, and minute in 
sequence, and then press 
Nx
.
“EXECUTING….” appears and the clock 
is set.
5
Press 
x
 to return to the normal 
display.
Note
If you do not press 
Nx
 within one minute 
of entering the clock setting data, the clock 
setting mode is cancelled and the window 
will return to the normal display.