SYMPTOM After replacing the EEPROM, a noisy playback picture may be experienced.
CAUSE
Corruption of data within the EEPROM.
ACTION
After setting the JP numbers and closing the test mode, turn off the mains
supply to the VCR. Enough time should be allowed for the the back-up capacitor
to discharge.
supply to the VCR. Enough time should be allowed for the the back-up capacitor
to discharge.
When the VCR is powered up again, the microprocessor will read the newly stored
hexadecimal codes from the EEPROM and the unit will perform correctly.
hexadecimal codes from the EEPROM and the unit will perform correctly.