Read Sharp LC-37AD1E (serv.man8) Service Manual online
28
LC-37AD1E
(7) Component HDTV signal adjustment
1
Setup
1. Input HDTV (1080i) component signal.
2. Select component source.
2. Select component source.
100% colour bar signal including 100% white, like
split field colour bar
split field colour bar
Adjustment items
Adjustment conditions
Adjustment procedures
2
MAIN COMP HDTV
CONTRAST
adjustment
CONTRAST
adjustment
Adjust the TP815 to have 0.95 ±0.025 Vp-p from the
pedestal level.
pedestal level.
(6) Component 15k Hz signal adjustment
1
Setup
1. Select component 15k Hz.
2. Select component source.
2. Select component source.
100% SMPTE colour bar or similar colour bar
signal including 100% white.
signal including 100% white.
Adjustment items
Adjustment conditions
Adjustment procedures
2
MAIN COMP 15k Y
CONTRAST
adjustment
CONTRAST
adjustment
Adjust pin (1) of P801 to 0.70±0.025 Vp-p.
3
MAIN COMP 15k
COLOR GAIN
adjustment
COLOR GAIN
adjustment
Adjust pin (3) of P801 to
0.70 ±0.025 Vp-p.
0.70 ±0.025 Vp-p.
4
MAIN COMP 15k Cr
LEVEL adjustment
LEVEL adjustment
Adjust pin (5) of P801 to
0.70 ±0.025 Vp-p.
0.70 ±0.025 Vp-p.
0.70V
0.70V
Page6
Page6
Page6
Click on the first or last page to see other LC-37AD1E (serv.man8) service manuals if exist.