Read Sharp PG-F320W (serv.man5) Service Manual online
PG-F320W
5 – 4
Power supply PWB check
Is 13 V applied to pins (2), (3) and (4)
of the connector P704?
NO
YES
Does the lamp turn on?
YES
Check the main PWB.
NO
Are connectors P704 and CN901 fully
inserted?
inserted?
NO
Securely insert the connectors.
YES
Is DC voltage of 380 V applied to both
ends of C740?
ends of C740?
NO
Is pin (11) of the connector P704 at
“H”?
“H”?
NO
Check the main PWB.
YES
YES
Check peripheral circuits of IC707.
Is F705 in the OPEN status?
NO
Is LAMP-EN/SYNC signal properly
sent to pin (14) of the connector
P704?
sent to pin (14) of the connector
P704?
(Refer to the waveform chart
.)
NO
Check the main PWB.
YES
YES
Check circuits F705 and after or
replace F705.
replace F705.
Are GATE waveforms of Q901 appro-
priate?
priate?
(See waveform diagram
.)
NO
Check the ballast PWB.
Are connectors P701 and P702 fully
inserted?
NO
Securely insert the connectors.
YES
Is AC voltage between 100 - 240 V
applied to both ends of C702?
applied to both ends of C702?
NO
Replace F701.
YES
Is the bimetal broken?
(Connection between 1 and 2 of
P702)
(Connection between 1 and 2 of
P702)
NO
Press the red button on the bimetal.
YES
Is R729 open?
NO
Is F704 open?
NO
Check peripheral circuits of IC704.
YES
YES
Check that P704 connector pin (11)
is at “H”. Replace R729.
is at “H”. Replace R729.
Replace F704.
Check that the power supply FAN
FB and FC are not stopped.
Check that the power supply FAN
FB and FC are not stopped.
1
1
6
1
Click on the first or last page to see other PG-F320W (serv.man5) service manuals if exist.