PG-F312X (serv.man3). The Optical Unit Outline - Sharp Projector Service Manual (repair manual). Page 2

Read Sharp PG-F312X (serv.man3) Service Manual online

XR-32S/XR-32X/PG-F212X/PG-F312X
3 – 2
2. When the DMD unit has been replaced.
If shading shown in Figure 1 appears on the screen after replacing DMD, turn the adjustment screw of the optical engine to adjust the lighting area of
DMD.
CAUTION: Please promptly adjust 2-1) when there is a shadow like Figure 1 after it lights 
and remove the shadow. 
1) Loosen the adjustment lever fixing screw 
. After adjusting the lighting area with the adjustment lever 
, tighten the adjustment lever fixing
screw .
2) When mounting DMD, tighten the 3 screws evenly.
Fig. 1
Shading
1
2
1
1
2
Tightening order: 1
2
3
Screw torque: 0.44 ± 0.05 N·m
2
1
3
Page of 3