Read Sharp MX-M160 / MX-M160D / MX-M160DK (serv.man32) Technical Bulletin online
1/2
ROM version upgrade ... (1),(2)
1. Model Name MX-M160D/M200D
2. Description
ROM version upgrade ... (2)
• OPE-ROM version upgrade (only for the models mounting the European panel)
Executed from the production in May, 2010
Target model
Version
Packing label
MCU
IMC
OPE
MX-M160 All
destinations
A02 01.01.00
01.00.00.
21.02.00
MX-M160D Europe/Australia/South
Africa
MX-M200D Europe/Australia/South
Africa/Brazil
Reason for change: The following problem has been fixed.
1. If set to Portuguese, the displayed message during FAX reception/print may get garbled.
ROM version upgrade ... (1)
• MCU-ROM version upgrade (all destinations)
• OPE-ROM version upgrade (for North America)
Executed from the production in January, 2010
Target model
Version
Packing label
MCU
IMC
OPE
MX-M160 All
destinations
A01 01.01.00
01.00.00.
21.00.00
MX-M160D
MX-M200D
MX-M200D
Europe/Australia
21.00.00
Holland
31.00.00
Austria
61.00.00
MX-M200D
For North America
11.01.00
Changes: Refer to the attached sheet.
Sharp Electronics (UK) Ltd., Document Systems Support
TECHNICAL BULLETIN
Date:
27 August 2010
Model:
MX-M160D/200D
Ref.:
DCE791
Colour:
White
Page:
1 of 2
2/2
3. Changes Version
(1)
No. Item
Description
1 Scanner
When returning from the power shutoff mode by scanner operation after entering it in the scan
screen state, scanning operation is conducted with the Ready message displayed. This
problem has been fixed.
screen state, scanning operation is conducted with the Ready message displayed. This
problem has been fixed.
2 Toner level warning
Even if toner near end, its information is not displayed on Web Page. This problem has been
fixed.
fixed.
3 FAX
When installing the FAX option with the destination incorrect, "F6-99" appears instead of
displaying the "F6-97" error. This problem has been fixed.
displaying the "F6-97" error. This problem has been fixed.
4 Web Page
When continuously registering speed dials from Web Page, the "F6-88" error may occur. This
problem has been fixed.
problem has been fixed.
5 Scanner
When scanning an A3 full-color original at a high resolution via Network Box, scanning may be
completed in the middle. This problem has been fixed.
completed in the middle. This problem has been fixed.
6 Energy saving
When the department management of FAX is enabled, if the auto clear time and power shutoff
time are set to the same value, hang-up may occur. This problem has been fixed.
time are set to the same value, hang-up may occur. This problem has been fixed.
7 Language added
Spanish has been added to the machines for North America.
Display