MX-7001N PAPER EXIT SECTION P – 5
5)
Remove the screws (H), and remove the earth plate (I).
Remove the E-ring (J), and remove the bearing (K). Remove
the E-ring (L), and remove the belt (M), the pulley (N), the par-
allel pin (O). Remove the paper exit roller 1 (Drive) (P).
Remove the E-ring (J), and remove the bearing (K). Remove
the E-ring (L), and remove the belt (M), the pulley (N), the par-
allel pin (O). Remove the paper exit roller 1 (Drive) (P).
e. Paper exit temperature detection PWB
1)
Remove the fusing unit. (Refer to the "[O] FUSING SEC-
TION".)
TION".)
2)
Remove the paper exit unit. (Refer to the "(1) Paper exit unit".)
3)
Remove the screws (A), and remove the fan cover (B).
4)
Remove the screw (C), and remove the paper exit temperature
detection PWB (D). Disconnect the connector (E).
detection PWB (D). Disconnect the connector (E).
f. Discharge brush
1)
Remove the fusing unit. (Refer to the "[O] FUSING SEC-
TION".)
TION".)
2)
Remove the paper exit unit. (Refer to the "(1) Paper exit unit".)
Unit
Parts
1
Paper exit unit
g
Paper exit temperature detection PWB
H
H
I
K
L
M
N
O
P
J
1-f
1-g
Unit
Parts
Mainte
nance
1
Paper exit unit
h
Discharge brush
✕
A
A
A
A
B
C
D
E
1-g
1-h