Connection of the ground wire to Fusing rear PG UN
[Step 1] Remove "Right cabinet rear upper". (Unscrew the screws indicated with
○
<x6>)
[Step 2] Remove FAX PWB together with the plate. (Unscrew the screws indicated with
○
<x 3>. Remove the connectors indicated with
□
<x2>)
[Step 3] Open the right door, and remove Fusing unit. (Unscrew the screws indicated with
○
<x2>)
Remove Fusing rear PG UN. (Unscrew the screw indicated with
○
<x1>)
Remove Fusing rear PG UN.
Fusing rear PG UN
Fusing UN
Disconnect the connector.
Right door
Right cabinet
rear upper
FAX PWB
[Step 4] Connect the ground wire to Fusing rear PG UN removed at Step 3.
[Step 5] Pass the ground wire to the rear side of the machine, and then mount Fusing rear PG UN.
Connect the
connector.
Disconnect the connector.
When mounting the unit, pass
the ground wire from the area
indicated with the red circle to
the rear side of the machine.
the ground wire from the area
indicated with the red circle to
the rear side of the machine.
Use this boss as the rotation stop of
the terminal.
the terminal.