Page 1 of 2
CHANGE OF THE DRAWER
SOLENOID CABLE
ARRANGEMENT
1.Model Name:
XE-A201/202/212/301
2.General:
Solenoid cables used to be twisted around the rib inside the lower
cabinet. However, it sagged inside the drawer owing to the way it was
twisted. The sagging solenoid cables touched the drawer when
opening and closing the drawer. In order to avoid this problem, we
have changed the solenoid cable arrangement inside the drawer. The
solenoid cables shall be fixed by tie on the rib inside the lower
cabinet.
cabinet. However, it sagged inside the drawer owing to the way it was
twisted. The sagging solenoid cables touched the drawer when
opening and closing the drawer. In order to avoid this problem, we
have changed the solenoid cable arrangement inside the drawer. The
solenoid cables shall be fixed by tie on the rib inside the lower
cabinet.
3.Symptom: The fuse blew out when the solenoid cables touched the drawer.
4.Cause:
The solenoid cables inside the drawer sagged owing to the variation
of the cable fastening method. The solenoid cables touched the rear
side of the drawer when opening and closing the drawer.
of the cable fastening method. The solenoid cables touched the rear
side of the drawer when opening and closing the drawer.
5.Action:
The fastening method of the solenoid cable at the drawer is as
follows:
follows:
Before Change:
The solenoid cables were twisted around the front side of the rib of
the lower drawer.
After Change:
The solenoid cables are fixed with a tie to the rear side of the rib
inside the lower cabinet.
Pulling the solenoid cables when fixed to the rear side of the rib with
a tie not only avoids the cables sagging but gives space between the
cables and the drawer.
The solenoid cables were twisted around the front side of the rib of
the lower drawer.
After Change:
The solenoid cables are fixed with a tie to the rear side of the rib
inside the lower cabinet.
Pulling the solenoid cables when fixed to the rear side of the rib with
a tie not only avoids the cables sagging but gives space between the
cables and the drawer.
(For the Field)
Fix the solenoid cables with a tie when replacing the drawers for
repairs or maintenance.
(For Production)
From mid-May 2006 production