XE-A101 (serv.man3). XEA101 Service Manual (Exc Parts, CCT Diags) - Sharp ECR Service Manual (repair manual). Page 4

Read Sharp XE-A101 (serv.man3) Service Manual online

7. DRAWER
[OUTLINE]
Standard equipment:
Yes (1)
Max. number of drawers: 1
The drawer consists of:
(1) Drawer box (outer case) and drawer
(2) Money case
(3) Coin case
(4) Lock (attached to the drawer)
[SPECIFICATION]
1) DRAWER BOX AND DRAWER
Size
330 (W) x 363 (D) x 98 (H) mm
13 (W) x 14.3 (D) x 3.9 (H) inches
Material
Plastic
Bell
Release lever
Standard equipment: situated at the bottom
Drawer open sensor
2) MONEY CASE
Separation from the drawer
Disallowed
Separation of the bill compartments from the coin
compartments
Allowed
Bill separator
Number of compartments
3B/5C
Layout:
3) LOCK (LOCK KEY : LKGIM7331BHZZ)
Location of the lock: Front
Method of locking and unlocking:
To lock, insert the drawer lock key into the
lock and turn it 90 degrees counter clockwise.
To unlock, insert the drawer lock key and turn
it 90 degrees clockwise.
Key No:
SK1-1
8. BATTERY
1) MEMORY BACK UP BATTERY
For memory back up, the dry battery R6 or LR6 ("AA" size) (3 pieces)
are needed.
1. Memory holding time:
Approx. 1 year after New dry batteries are installed.
2. Battery exchange method:
When the low battery symbol "L" lights up, replace the batteries (3
AA) replaced by the following method;
1) Power on the ECR.
2) Mode switch turn to "REG" mode.
3) Remove the OLD dry batteries (3 pieces).
4) Insert the NEW dry batteries (3 pieces).
5) Confirm the low battery symbol "L" is off.
2) LOW BATTERY
Low battery indication will appear on the left side of display when the
battery voltage is low.
CASE 1: When sitting idle or after completion of transaction.
The machine can indicate the low battery condition (Always)
CASE 2: Low battery indication will not appear during key opera-
tions, but will appear after power up of the cash register.
[Display sample]
"    0.00" : Battery is OK.
"L  0.00" : Low battery (You have to change the batteries.)
After finalization
"F  12.34" : Battery is OK.
"L  12.34" : Low battery ("L" indicate instead of "F".)
3) NO BATTERY
If the user forgets to replace the battery and the battery voltage falls
below a certain level, or if a power failure occurs with no batteries
installed, the memory contents cannot be retained. The CPU judges it
as no battery and performs the master reset. In this case, all the
settings and registrations are cleared. If, however, the power is con-
tinuously supplied to the AC cord, the memory contents are retained.
Low battery : Batteries are installed, but the voltage is low.
Memory back up can be done.
No battery
: Batteries are not installed or the voltage is extremely
low.
The master reset is executed when a power failure
occurs, when the batteries are not properly changed.
Low battery & No battery indication will appear at the most left posi-
tion of display when the battery voltage is low.
CASE 1: When any numeric entry & item entry is not done or just
after finalization.
The machine can indicate the battery condition. (Always)
CASE 2: When numeric entry or item entry is done.
Battery condition is not appeared.
Exceptionally, at the power is restored after power failure, the
low battery & No battery indication will appear on the display
only when the battery voltage is low.
And the indication will disappear after any key entry.
[Display sample]
"
0.00" : Battery is OK.
"L 0.00" : Low battery
"L 0.00" : No battery
After finalization
"F 12.34" : Battery is OK.
"L 12.34" : Low battery ("L" indicate instead of "F".)
"L 12.34" : No battery ("L" indicate instead of "F".)
3B/5C
L
L
Page of 12
Display

Click on the first or last page to see other XE-A101 (serv.man3) service manuals if exist.