Read Sharp DV-SL10H (serv.man8) Service Manual online
1-7-4
TESTMODE
[ ERROR RATE MEASUREMENT]
1. Turn on the power to the player, remove the disk
from the tray, and close the tray.
2. To put the DVD player into test mode, press [1], [2],
[3], [4], and [ON SCREEN] buttons on the remote
control unit in that order.
The unit will switch to Test Mode and Fig. a will be
displayed. For VFD, the current F/W version will be
displayed. (Fig. b)
control unit in that order.
The unit will switch to Test Mode and Fig. a will be
displayed. For VFD, the current F/W version will be
displayed. (Fig. b)
(model name) VERSION
REGION
1. TEST1-VFD
2. TEST2-REPEAT PLAY
2. TEST2-REPEAT PLAY
3.
TEST3-
EEPROM CLEAR
4.
TEST4-
MEASUREMENT SERVO
5.
TEST5-
DISC READ CHECK
6.
TEST6-
MECHA CHECK
7.
TEST7-
DISC INFO
8.
TEST8-
ERROR RATE
EXIT:
.
POWER
Fig. a Test Mode Screen
Fig. b Sample VFD in Test Mode
3. Press the [8] button to select "8. TEST 8 - ERROR
RATE." The on-screen display will change to the
screen shown in Fig. c. The VDF display will change
to the display shown in Fig. d.
screen shown in Fig. c. The VDF display will change
to the display shown in Fig. d.
(model name) VERSION
REGION
TEST8-ERROR RATE
DISC:DVD-V / DUAL LAYER / OPPOSITE
STA:
STATUS:
CHECK : OK
NOW MEASURE : L
DISC:DVD-V / DUAL LAYER / OPPOSITE
STA:
STATUS:
CHECK : OK
NOW MEASURE : L
RETURN:
.
EXIT:
POWER
RETURN
1
5
H
/
2
H
H
/
3
H
/
4
H
PO1st
00000 00000 00000 00000 00000
00000 00000 00000 00000 00000
00000 00000 00000 00000 00000
Correct
Uncorrect
PI1st
PO2nd
PO3rd
PI2nd
(I) With a DVD inserted.
(model name) VERSION
REGION
TEST8-ERROR RATE
DISC: CD
STA:
STATUS:
CHECK : OK
NOW MEASURE :
DISC: CD
STA:
STATUS:
CHECK : OK
NOW MEASURE :
RETURN:
.
EXIT:
POWER
RETURN
5
H
TRK
:
:
00000
00000
00000
C1 Correct
C2 Uncorrect
C2 Uncorrect
:
:
(II) With a CD/VCD inserted.
Fig. c TEST8-ERROR RATE MODE
Fig. d Sample VFD in TEST8-ERROR RATE MODE
4. Put disk to be checked into the tray. Close the tray
using either the [OPEN/CLOSE] or [PLAY] button on
the unit or on the remote. The disk will automatically
be distinguished and error rate measurement will
begin.
Fig. c will display:
the unit or on the remote. The disk will automatically
be distinguished and error rate measurement will
begin.
Fig. c will display:
1
Inserted disk’s inner parameter (For DVD, Layer
0, initial address)
0, initial address)
2
Inserted disk’s outer parameter (For DVD, Layer
0, final address)
0, final address)
3
Inserted disk’s Layer 1, initial address.
4
Inserted disk’s Layer 1, final address.
Depending on the contents of the inserted disk, 3
and 4 above may not be displayed.
Once the error rate measurement has started, if the
largest value resulting from the first three measure-
ments has a value of 2000 or less, and all values in
the "Uncorrect" row are 0, the message "CHECK :
OK" will be displayed on area
and 4 above may not be displayed.
Once the error rate measurement has started, if the
largest value resulting from the first three measure-
ments has a value of 2000 or less, and all values in
the "Uncorrect" row are 0, the message "CHECK :
OK" will be displayed on area
5
.
If the largest value is greater than 2000, the mes-
sage "CHECK : NG" will be displayed on area
sage "CHECK : NG" will be displayed on area
5
.
5. "Correct" and "Uncorrect" in Fig. c:
(1) For DVDs the following will be displayed:
PO1st-Correct count; PO1st-Uncorrect count;
PI1st-Correct count; PI1st-Uncorrect count;
PO2nd-Correct; PO2nd-Uncorrect count;
PI2nd-Correct count; PI2nd-Uncorrect count;
PO3rd-Correct count; PO3rd-Uncorrect count.
The above ten numerical values will be displayed for
each 80 ECC block.
PO1st-Correct count; PO1st-Uncorrect count;
PI1st-Correct count; PI1st-Uncorrect count;
PO2nd-Correct; PO2nd-Uncorrect count;
PI2nd-Correct count; PI2nd-Uncorrect count;
PO3rd-Correct count; PO3rd-Uncorrect count.
The above ten numerical values will be displayed for
each 80 ECC block.
(2) For CD/VCDs the following will be displayed:
C1-Correct count; C2-Uncorrect count.
The values for these two items will be displayed
every 7350x4 frames.
For VFD, the following will be displayed:
PO1st-Correct count; (C1-Correct count for CDs).
(Fig. e)
C1-Correct count; C2-Uncorrect count.
The values for these two items will be displayed
every 7350x4 frames.
For VFD, the following will be displayed:
PO1st-Correct count; (C1-Correct count for CDs).
(Fig. e)
Fig. e: Sample VFD display of ERROR RATE
measurement
measurement
6. To end the ERROR RATE measurement, press the
[OPEN/CLOSE] button on either the unit or the
remote. After the display has ceased, press the
[POWER] button on either the unit or the remote to
shut off the power.
remote. After the display has ceased, press the
[POWER] button on either the unit or the remote to
shut off the power.