• Main line Test Mode  (TEST 8)
Function:
1. check communication from main micon to DAB unit when without DAB unit.
2. Check volume IC (75341) DAB channel condition.
3. supply condition check
Note:
At test mode 8, there is not DAB unit.
GO TO POWER OFF MODE.
WHILST HOLDING DOWN THE  "PRESET UP" and  "BASS/TREBLE"  BUTTON, PRESS THE 
POWER BUTTON.
(chataring: 10ms x 3)
1 .DISPLAY "Communicate" FOR 1 SECOND
2. Set Volume IC (75341) to DAB channel 
3. Set mute off but when volume change to 0 set mute on
Push "preset select" key and change "SCP_CLK"  & "SI_DIN" & "SI_DOUT" as follows: (need 
display statue on LCD, first line display "CLK DIN DOUT", second line display Pin status.)
CLK
DIN
DOUT
0
1
0
0
1
0
0
1
0
1
0
0
0
1
1
TEST8
Push "power" key to enter into standby mode