Read Panasonic TX-32AR400 Service Manual online
Panasonic Corporation 2014.
ORDER NO.PCZ1405127CE
LCD TV
Model No.
TX-32AR400
2
TABLE OF CONTENTS Page
1 Safety Precaution ------------------------------------------------------------------------------------------------ 3
1.1. General Guidelines ---------------------------------------------------------------------------------------- 3
2 Warning ------------------------------------------------------------------------------------------------------------- 4
2.1. Prevention of Electrostatic Discharge(ESD) to Electrostatically Sensitive(ES) Devices 4
2.2. About lead free solder (PbF) ---------------------------------------------------------------------------- 5
3 Service Navigation ----------------------------------------------------------------------------------------------- 6
3.1. Service Hint -------------------------------------------------------------------------------------------------- 6
3.2. Applicable signals ------------------------------------------------------------------------------------------ 7
4 Specifications ----------------------------------------------------------------------------------------------------- 8
5 Troubleshooting Guide ----------------------------------------------------------------------------------------
- 9
5.1. No Power----------------------------------------------------------------------------------------------------
- 9
5.2. Abnormal Display ----------------------------------------------------------------------------------------- 1
0
5.3 No Display --------------------------------------------------------------------------------------------------- 1
1
5.4 Sound Problem --------------------------------------------------------------------------------------------- 1
2
5.5 Remote Control Malfunction ---------------------------------------------------------------------------- 1
3
6 Disassembly and Assembly Instructions --------------------------------------------------------------- 1
4
7 Block Diagram ----------------------------------------------------------------------------------------------------
18
8 Wiring Connection Diagram ---------------------------------------------------------------------------------
19
8.1. Caution Statement --------------------------------------------------------------------------------------
19
8.2. Wiring --------------------------------------------------------------------------------------------------------
19
9 Exploded View and Replacement Parts List ----------------------------------------------------------- 2
0
9.1. Exploded View --------------------------------------------------------------------------------------------- 2
0
9.2. Replacement Parts List ---------------------------------------------------------------------------------- 2
2
3
1 Safety Precautions
1.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been
overheated or damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are
properly installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to
shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or
some of the wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the
entire wiring unit instead.
entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug
them straight out.
1.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between
the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When
the exposed metallic part has a return path to the
chassis, the reading should be 100 Mohm and
over. When the exposed metal does not have a
return path to the chassis, the reading must be
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When
the exposed metallic part has a return path to the
chassis, the reading should be 100 Mohm and
over. When the exposed metal does not have a
return path to the chassis, the reading must be
.
1.1.2. Leakage Current Hot Check (See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do
not use an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel
with 0.15μF capacitors, between each exposed
metallic part on the set and a good earth ground
such as a water pipe, as shown in Figure 1.
metallic part on the set and a good earth ground
such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or
more sensitivity, to measure the potential
across the resistor.
across the resistor.
4. Check each exposed metallic part, and
measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and
repeat each of the above measurements.
6. The potential at any point should not exceed
0.75 volts RMS. A leakage current tester
(Simpson Model 229 or equivalent) may be
used to make the hot checks, leakage current
must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified,
there is a possibility of a shock hazard, and the
equipment should be repaired and rechecked
before it is returned to the customer.
(Simpson Model 229 or equivalent) may be
used to make the hot checks, leakage current
must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified,
there is a possibility of a shock hazard, and the
equipment should be repaired and rechecked
before it is returned to the customer.
Figure 1
4
2 Warning
2.1. Prevention of Electrostatic Discharge (ESD) to Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by static electricity. Such components commonly
are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some
field-effect transistors and semiconductor [chip] components. The following techniques should be used to help
reduce the incidence of component damage caused by electrostatic discharge (ESD).
are called Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some
field-effect transistors and semiconductor [chip] components. The following techniques should be used to help
reduce the incidence of component damage caused by electrostatic discharge (ESD).
1. Immediately before handling any semiconductor component or semiconductor-equipped assembly, drain off
any ESD on your body by touching a known earth ground. Alternatively, obtain and wear a commercially
available discharging ESD wrist strap, which should be removed for potential shock reasons prior to applying
power to the unit under test.
available discharging ESD wrist strap, which should be removed for potential shock reasons prior to applying
power to the unit under test.
2. After removing an electrical assembly equipped with ES devices, place the assembly on a conductive surface
such as aluminum foil, to prevent electrostatic charge buildup or exposure of the assembly.
3. Use only a grounded-tip soldering iron to solder or unsolder ES devices.
4. Use only an anti-static solder removal device. Some solder removal devices not classified as [anti-static (ESD
4. Use only an anti-static solder removal device. Some solder removal devices not classified as [anti-static (ESD
protected)] can generate electrical charge sufficient to damage ES devices.
5. Do not use freon-propelled chemicals. These can generate electrical charges sufficient to damage ES devices.
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to
6. Do not remove a replacement ES device from its protective package until immediately before you are ready to
install it. (Most replacement ES devices are packaged with leads electrically shorted together by conductive
foam, aluminum foil or comparable conductive material).
foam, aluminum foil or comparable conductive material).
7. Immediately before removing the protective material from the leads of a replacement ES device, touch the
protective material to the chassis or circuit assembly into which the device will be installed.
Caution
Be sure no power is applied to the chassis or circuit, and observe all other safety precautions.
8. Minimize bodily motions when handling unpackaged replacement ES devices. (Otherwise ham less motion
such as the brushing together of your clothes fabric or the lifting of your foot from a carpeted floor can generate
static electricity (ESD) sufficient to damage an ES device).
static electricity (ESD) sufficient to damage an ES device).