RR-US065E - Panasonic Audio Service Manual (repair manual). Page 7

Read Panasonic RR-US065E Service Manual online

7
4 Test Mode
4.1.
Operation Check Mode
This unit is equipped with the functions to check it to record or
playback usually, the display of LCD and USB connection.
Caution
When the checking operation is performed, all recorded
data will be cleared.
Note:
• When there are no available items of any track, the unit can
not be operated to check it to record and playback.
To continue record and playback check, erase unneeded
items.
• For operation check mode, external microphone(not
included), Stereo earphone(included), USB cable(included),
and computer are necessary.
4.1.1.
To Enter Operation Check
1. The state of SET is confirmed.
• MEETING/DICTATION switch: DICTATION position
• SPEED CONTROL switch: ON
• MICROPHONE DIRECTIONAL switch: OFF
2. Set the HOLD mode.
3. While hold down the REC MODE switch and press the
REC/PAUSE switch, While hold down the REC/PAUSE
switch press the REC MODE switch at short time.
Note:
The item 3 shown above should be operate within 1
seconds.
4. After all segment of LCD lights up, the unit is entered to
Operation Check Mode. During the Operation Check
Mode, the Recording LED is blinking.
4.1.2.
Operation Check Method
Note:
The LCD indications shown below are examples of opera-
tion check mode with the folder A and no recording data.
1. Check all segment of LCD lights up. 
(Fig.1)
2. Release the HOLD mode.
3. Check the display of LCD is displayed as shown below. 
(Fig.2)
4. Press the VOL+ switch: The figure increases.
5. Press the VOL- switch: The figure decreases.
6. Press the REC STOP
→REC MODE→A-B repeat switch
and adjust to the MEETING/DICTATION: MEET-
ING
→SPEED CONTROL: OFF.
7. Check the display of LCD is displayed as shown below. 
(Fig.3)
8. Press the PLAY switch.
9. Check the display of LCD is displayed as shown below.  
(Fig.4)
10. Press the FORWARD switch.
11. Adjust to the MICROPHONE DIRECTION switch: OFF.
12. The recording begining. (HQ-Monaural) (MICROPHONE
DIRECTIONAL[OFF], MICROPHONE sensitivity: Hi)
13. Make sure that LCD recording level indication moves, the
Page of 33
Display

Click on the first or last page to see other RR-US065E service manuals if exist.