Read Panasonic CS-XE9HKD / CS-XE12HKD / CU-XE9HKD / CU-XE12HKD Service Manual online
65
17.2. Sensible Capacity Chart
O CS-XE9HKD CU-XE9HKD
O CS-XE12HKD CU-XE12HKD
220 - 230V
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
2.58
1.96
0.54
2.41
1.88
0.58
2.24
1.80
0.62
2.04
1.71
0.67
19.0
qC
2.60
0.59
19.5
qC
2.83
2.05
0.55
2.65
1.97
0.59
2.46
1.89
0.63
2.24
1.80
0.68
22.0
qC
3.09
2.12
0.56
2.88
2.04
0.60
2.68
1.97
0.64
2.44
1.88
0.70
220 - 230V
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
3.47
2.63
0.87
3.24
2.52
0.94
3.02
2.43
1.00
2.74
2.30
1.08
19.0
qC
3.50
0.95
19.5
qC
3.81
2.76
0.89
3.56
2.65
0.95
3.31
2.55
1.02
3.01
2.43
1.10
22.0
qC
4.15
2.86
0.90
3.88
2.75
0.97
3.61
2.65
1.04
3.28
2.53
1.12
TC
SHC
IP
SHC
IP
-
-
-
-
-
Total Cooling Capacity (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Sensible Heat Capacity (kW)
Input Power (kW)
Indoor 27
qC/19qC
Outdoor 35
qC/24qC
Click on the first or last page to see other CS-XE9HKD / CS-XE12HKD / CU-XE9HKD / CU-XE12HKD service manuals if exist.