Read Panasonic CS-E21HKDS / CS-E24HKDS / CU-E21HKD / CU-E24HKD Service Manual online
72
17.2. Sensible Capacity Chart
CS-E21HKDS CU-E21HKD
CS-E24HKDS CU-E24HKD
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.25
4.74
2.02
5.84
4.54
2.18
5.43
4.37
2.33
4.94
4.15
2.51
19.0
qC
6.30
2.21
19.5
qC
6.86
4.96
2.06
6.41
4.77
2.22
5.97
4.59
2.37
5.42
4.37
2.56
22.0
qC
7.48
5.14
2.10
6.99
4.95
2.26
6.50
4.77
2.42
5.91
4.55
2.61
Outdoor Temp. (
qC)
Indoor wet
bulb temp.
bulb temp.
30
35
40
46
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
TC
SHC
IP
17.0
qC
6.75
5.11
1.94
6.30
4.90
2.09
5.86
4.71
2.23
5.33
4.48
2.41
19.0
qC
6.80
2.12
19.5
qC
7.41
5.35
1.98
6.92
5.14
2.13
6.44
4.95
2.28
5.85
4.71
2.45
22.0
qC
8.07
5.55
2.01
7.54
5.34
2.17
7.02
5.15
2.32
6.38
4.91
2.50
TC - Total Cooling Capacity (kW)
Indoor 27
qC/19qC
SHC - Sensible Heat Capacity (kW)
Outdoor 35
qC/24qC
IP - Input Power (kW)