CS-E21HKDS, CS-E24HKDS, CU-E21HKD, CU-E24HKD - Panasonic Air Conditioner Service Manual (repair manual). Page 6

Read Panasonic CS-E21HKDS / CS-E24HKDS / CU-E21HKD / CU-E24HKD Service Manual online

6
1. Cooling capacities are based on indoor temperature of 27
qC Dry Bulb (80.6qF Dry Bulb), 19.0qC Wet Bulb (66.2qF Wet Bulb)
and outdoor air temperature of 35
qC Dry Bulb (95qF Dry Bulb), 24qC Wet Bulb (75.2qF Wet Bulb)
2. Heating capacities are based on indoor temperature of 20
qC Dry Bulb (68qF Dry Bulb) and outdoor air temperature of 7qC Dry
Bulb (44.6
qF Dry Bulb), 6qC Wet Bulb (42.8qF Wet Bulb)
Note
• Specifications are subject to change without notice for further improvement.
Fan
Type
Cross-Flow Fan
Propeller Fan
Material
ASHT-18
PP
Motor Type
Transistor (8-pole)
Transistor (8-pole)
Input Power
W
68
74.8
Output Power
W
30
40
Fan Speed
Q-Lo (Cool/Heat)
rpm
 1100 / 1190
Lo (Cool/Heat)
rpm
 1160 / 1250
Me (Cool/Heat)
rpm
1330 / 1425
Hi (Cool/Heat)
rpm
1500 / 1600
700 / 680
SHi (Cool/Heat)
rpm
1660 / 1680
Heat Exchanger
Fin Material
Aluminium (Pre Coat)
Aluminium (Blue Coated)
Fin Type
Slit Fin
Corrugated Fin
Row x Stage x FPI
2 x 15 x 19
2 x 34 x 18
Size (W x H x L)
mm
810 x 315 x 25.4
36.4 x 714 x 803
831
Air Filter
Material
Polypropelene
Type
One-Touch
Item
Unit
Power Source (Phase, Voltage, Cycle)
ø
Single
V
220  - 230
Hz
50
Input Power
W
Cooling; 2.21k (215 ~ 2.54k)
Heating; 2.10k (245 ~ 2.75k)
Starting Current
A
9.7
Running Current
A
Cooling; 10.4 - 9.9
Heating; 9.7 - 9.3
Maximum Current
A
12.6
Power Factor
%
Cooling; 97
Heating; 98
Power factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Power Cord
Number of core
Length
m
Thermostat
Electronic Control
Protection Device
Electronic Control
ITEM
UNIT
INDOOR UNIT
OUTDOOR UNIT