Read Panasonic CS-BE25TKE / CS-BE35TKE / CS-BE50TKE / CU-BE25TKE / CU-BE35TKE / CU-BE50TKE (serv.man2) Service Manual online
8
Model
Indoor CS-BE50TKE
Outdoor CU-BE50TKE
Performance Test Condition
EUROVENT
Power Supply
Phase, Hz
Single, 50
V 220
230
Min. Mid. Max. Min. Mid. Max.
Cooling
Capacity
kW
0.98 5.00 5.40 0.98 5.00 5.40
BTU/h
3340 17100 18400 3340 17100 18400
kcal/h
840 4300 4640 840 4300 4640
Running
Current
A
– 7.90 – – 7.60 –
Input
Power
W
285 1.70k 1.91k 285 1.70k 1.91k
Annual
Consumption kWh
– 850 – – 850 –
EER
W/W
3.44 2.94 2.83 3.44 2.94 2.83
BTU/hW 11.72 10.06 9.63 11.72 10.06 9.63
kcal/hW 2.95 2.53 2.43 2.95 2.53 2.43
ErP
Pdesign kW
5.0
5.0
SEER (W/W)
5.9
5.9
Annual
Consumption
kWh 297
297
Class
A+
A+
Power
Factor
%
– 98 – – 97 –
Indoor Noise
dB-A (H/L/Q-Lo)
44 / 37 / 34
44 / 37 / 34
Power Level dB
60 / 53 / 50
60 / 53 / 50
Outdoor Noise
dB-A (H/L/Q-Lo)
48 / - / -
48 / - / -
Power Level dB
63 / - / -
63 / - / -
Heating
Capacity
kW
0.98 5.40 7.50 0.98 5.40 7.50
BTU/h
3340 18400 25600 3340 18400 25600
kcal/h
840 4640 6450 840 4640 6450
Running
Current
A
– 7.45 – – 7.10 –
Input
Power
W
350 1.59k 2.46k 350 1.59k 2.46k
COP
W/W
2.80 3.40 3.05 2.80 3.40 3.05
BTU/hW 9.54 11.57 10.41 9.54 11.57 10.41
kcal/hW 2.40 2.92 2.62 2.40 2.92 2.62
ErP
Pdesign kW
4.0
4.0
Tbivalent °C
-10
-10
SCOP (W/W)
4.0
4.0
Annual
Consumption
kWh 1400
1400
Class
A+
A+
Power
Factor
%
– 97 – – 97 –
Indoor Noise
dB-A (H/L/Q-Lo)
44 / 37 / 34
44 / 37 / 34
Power Level dB
60 / 53 / 50
60 / 53 / 50
Outdoor Noise
dB-A (H/L/Q-Lo)
49 / - / -
49 / - / -
Power Level dB
64 / - / -
64 / - / -
Low Temp. : Capacity (kW) / I.Power (W) / COP
5.43 / 2.18k / 2.49
Extr Low Temp. : Capacity (kW) / I.Power (W) / COP
4.58 / 2.10k / 2.18
Max Current (A) / Max Input Power (W)
11.4 / 2.47k
Starting Current (A)
7.90
Click on the first or last page to see other CS-BE25TKE / CS-BE35TKE / CS-BE50TKE / CU-BE25TKE / CU-BE35TKE / CU-BE50TKE (serv.man2) service manuals if exist.