ON STAGE III IIIP (serv.man2) - JBL Audio EMC - CB Certificate (repair manual). Page 74

Read JBL ON STAGE III IIIP (serv.man2) EMC - CB Certificate online

 
 
<12014238 001 > 
 
 
Page 73 of 77 
 
AS/NZS 3112 (Partial) 
Clause 
Requirement − Test 
Result – Remark 
Verdict 
 
 
 
The material of the pin-insulation shall be 
resistant to the stresses to which it may be 
subjected at the high temperature likely to occur 
in conditions approaching the bad connection 
conditions and at low temperatures in particular 
conditions of service. 
 
 
Compliance shall be checked by the tests of 
Clause 2.13.13.2 to 2.13.13.5 
 
P  
 
(a) Pressure test at high temperature (2.13.13.2) 
 
P  
 
A specimen of one insulated pin only shall be 
subjected to the following test by means of the 
apparatus shown in Figure 2.2. This apparatus 
shall have a blade having a round shape with a 
diameter of 6 mm and a thickness of 0.7 mm. 
 
P  
 
The specimen shall be placed in position as 
shown in the Figure 2.5 and a force of 2.5 N shall 
be applied through the blade to specimen. 
 
P  
 
The apparatus, with the specimen in position, 
shall be maintained for 2 h in a heating cabinet at 
a temperature of 200+5ºC. The specimen shall 
then be removed from the apparatus and within 
10 s, cooled by immersion in cold water. 
 
 
The thickness of the insulation shall be measured 
immediately at the point of impression. 
 
 
The thickness within the area of the impression 
shall be not less than 50% of the thickness 
measured before the test. 
 
 
Visual inspection shall be made and no cracks on 
the insulation material shall be visible with normal, 
or corrected to normal, vision without additional 
magnification, and the dimension of the insulating 
material shall not have changed below the 
minimum size shown in Figure 2.4. 
 
 
(b) Static damp heat test (2.13.13.3) 
 
 
An insulated pin plug shall be subjected to two 
damp heat cycles in accordance with IEC 60068-
2-30. Db (12+12 h cycle), 95% relative humidity, 
lower temperature 25+3ºC and upper temperature 
40ºC. 
 
Page of 78
Display

Click on the first or last page to see other ON STAGE III IIIP (serv.man2) service manuals if exist.