IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
 
TRF No.:IECEN60950_1B 
 
TRF originator: SGS Fimko 
2.8.8 
Mechanical actuators 
 
N/A 
 
 
 
 
2.9 
Electrical insulation 
2.9.1 
Properties of insulating materials 
Natural rubber, asbestos or 
hygroscopic material is not 
used. 
2.9.2 
Humidity conditioning 
48hr 
 
Humidity (%)  ........................................................:  95% R.H. 
 
 
Temperature (°C) .................................................:  25°C 
 
2.9.3 
Grade of insulation 
Insulation complies with sub-
clauses 2.10, 4.5.1 and 5.2. 
 
2.10 
Clearances, creepage distances and distances through insulation 
2.10.1 
General  
See 2.10.3, 2.10.4 and 2.10.5. 
2.10.2 
Determination of working voltage 
The rms and the peak voltage 
were measured on the direct 
plug-in adaptor. 
The unit was connected to a 
240Vac power supply and 
floating secondary circuits was 
assumed to be earthed at 
the point by which the highest 
working voltage is obtained. 
Results see appended table 
2.10.2. 
2.10.3 
Clearances 
See below and advantage of 
annex G is not considered. 
2.10.3.1 
General 
See below, Annex G was not 
considered. 
2.10.3.2 
Clearances in primary circuits 
Annex F and minimum 
clearances considered. 
2.10.3.3 
Clearances in secondary circuits 
(See appended table 2.10.3 
and 2.10.4) 
2.10.3.4 
Measurement of transient voltage levels 
No transient voltage across the 
clearance lower than due or 
normal. 
N/A 
2.10.4 
Creepage distances 
(see appended table 2.10.3 
and 2.10.4)  
 
CTI tests ...............................................................:  CTI rating for all materials of 
min. 100. 
 
2.10.5 
Solid insulation 
See below. 
2.10.5.1 
Minimum distance through insulation 
(see appended table 2.10.5)  
Page of 78