Read Harman Kardon HK 3380 (serv.man11) EMC - CB Certificate online
- Page 14 of 32 -
www.nemko.com
Report No. 65742
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
14 COMPONENTS
14.1 Resistors
N
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
No such resistors
N
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
Not used
N
b) Resistors separately approved .......................... :
N
14.2
Capacitors and RC units
P
Capacitors separately approved
Yes,
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition .. :
No Y capacitors
N
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition .. :
C621 and C631 capacitors are
Certified components by
IEC 60384-14, 2
Certified components by
IEC 60384-14, 2
nd
edition
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ...................... :
connected to the mains: tests for X2 ...................... :
No such capacitors
N
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better ....................................................................... :
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ........................................ :
Several E. cap. Vol. >1750mm
3
,
but metal cases.
N
Shielded by a barrier to V-0 or metal ..................... :
N
14.3
Inductors and windings
See below.
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
Transformers evaluated
according to 14.3.3, 14.3.4
and 14.3.5
according to 14.3.3, 14.3.4
and 14.3.5
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ............................... :
manufacturer's name and type ............................... :
Adequate marking applied.
- Type no. and,
-.Manufacturer’s ID
- Type no. and,
-.Manufacturer’s ID
P
Transformers and inductors separately approved . :
No
N
14.3.2 General
Isolating transformer
P
14.3.3 Constructional
requirements
P
TRF No: IEC/EN 60065F
Click on the first or last page to see other HK 3380 (serv.man11) service manuals if exist.