AVR 505 (serv.man13) - Harman Kardon Audio EMC - CB Certificate (repair manual). Page 39

Read Harman Kardon AVR 505 (serv.man13) EMC - CB Certificate online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 37 - 
 
 
   
 Order 
No. 
11151
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
25,2 °C 
Rated voltage   
230V~ 50Hz 
Remarks  
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D104 
S-c 
254,4 
A - C 
30 min 
F907 
1,26 A 
Normal operating. 
Input current stabilised at 1,26A. 
No component damaged. 
No hazard. 
C122 S-c 
254,4 - 
hr 
31 min. 
F907 
1,70 A 
FL display off immediately. 
Input current stabilised at 1,94A. 
R101, R112, Q104 damaged. 
Main transformer primary winding 
heated-up to 144K and thermal fuse 
opened after 1 hr 31 min. 
Dielectric strength test O.K. 
No hazard. 
C119 S-c 
254,4 - 
hr 
10 min. 
F907 
1,53 A 
FL display off immediately. 
Q104 damaged. 
Main transformer primary winding 
heated-up to 141K and thermal fuse 
opened after 2 hr 10 min. 
Dielectric strength test O.K. 
No hazard. 
C117 
S-c 
254,4 
20 min 
F907 
1,25 A 
Normal operating. 
Input current stabilised at 1,24A. 
No component damaged. 
No hazard. 
D991 
S-c 
207 
AC - + 
10 min 
F907 
F903 
F904 
- Normal 
operating. 
Input current stabilised at 1,13A. 
F904 opened. 
No hazard. 
D991 
S-c 
254,4 
AC - + 
10 min 
F907 
F903 
F904 
- Normal 
operating. 
Input current stabilised at 1,19A. 
F904 opened. 
No hazard. 
C902 S-c 
207  - 
10 
min 
F907 
F903 
F904 
Front, Center channels signal output 
off immediately. 
Input current stabilised at 0,57A. 
F903, F904 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
Page of 49
Display

Click on the first or last page to see other AVR 505 (serv.man13) service manuals if exist.